Outdoor Single-pole voltage transformer JNT SM

Instrument voltage transformers (VT) JNT SM are designed to transmit measurement information signals to measuring instruments, protective devices, automation, signaling and control in voltage networks from 3.3 to 42 kV AC with a frequency of 50 or 60 Hz.

JNT SM voltage measuring transformers are designed for outdoor installation.

According to the principle of operation, they are inductive, single-phase, single-pole, grounded. Voltage transformers (VT) have a cast housing made on the basis of an epoxy compound. The insulation material of voltage transformers has excellent arc, ozone and ultraviolet protection characteristics, while it has high mechanical strength, so that the transformers can work for more than 30 years without any maintenance. The creepage distance and discharge distance of JNT SM voltage transformers are designed for high levels of air pollution.

Additionally, measuring voltage transformers, at the request of the customer, can be equipped with a ferroresonance protection device.

MAIN SPECIFICATIONS

  • Rated primary voltage from 3.3 to 42 kV
  • Rated secondary voltage 100.100/√3, 110.110/√3 ,120.120/√3
  • Number of secondary windings up to 3
  • Winding accuracy class for measurement 0.2; 0.5
  • Winding accuracy class for protection 3P;6P
  • Voltage factor 1.5 or 1.9
  • Ambient conditions: temperature from -45° to +55°
  • Compliance with IEC and IEEE standards or equivalent standards

ADVANTAGES OF VOLTAGE MEASURING TRANSFORMERS WITH CAST RESIN

  • Lack of any maintenance throughout the entire period of operation
  • Fire and explosion-proof design
  • Possibility of installation in any plane
  • High loads for all accuracy classes
  • Low partial discharge (PD)
  • Resistance to aggressive environmental conditions
  • The hydrophobic material exhibits excellent outdoor performance and also minimizes the possibility of arcing.
  • No ozone depleting gases

Voltage transformers (VT) of the JNT SM series were developed for operation at transformer substations, at traction substations of railways, hard-to-reach objects where equipment maintenance is not required, at enterprises with high pollution of electrical equipment.

Transformers meet the requirements of IEC, ANSI, IEEE, GOST standards.

Measuring voltage transformers JNT SM are a good alternative to obsolete and obsolete voltage transformers with oil insulation.

 

Outdoor Voltage Transformer, Outdoor Cast Resin Voltage Transformer, Voltage Transformer 6 kV, Voltage Transformer 7.2 kV, Voltage Transformer 10 kV, Voltage Transformer 12 kV, Voltage Transformer 15 kV, Voltage Transformer 17.5 kV, Voltage transformer 27 kV, Voltage transformer 35 kV, Voltage transformer 36 kV, Voltage transformer 38 kV, Voltage transformer 40.5 kV